O General Ducted Split AC 4.0 Ton R32 Inverter ARGH48CMTA-U
O General Ducted Split AC 4.0 Ton R32 Inverter ARGH48CMTA-U
O General Ducted Split AC 4.0 Ton R32 Inverter ARGH48CMTA-U

O General Ducted Split AC 4.0 Ton R32 Inverter ARGH48CMTA-U

O General Air Conditioners

Regular price Sale

O General 4.0 Ton (48,000 BTU) – ARGH48CMTA-U / AOGH48CRTA-U

Product Overview: Stepping into the light commercial range, the ARGH48CMTA-U is a 4 Ton (around 48,000 BTU class) ducted split system. This model requires a 380–415V three-phase power supply, reflecting its higher capacity and usage in larger spaces. It’s engineered for villas with extensive floor areas, open-plan offices, restaurants, or retail floors (~70–80 m²) that need powerful centralized cooling. The indoor unit for the 48k model is larger in cross-section than the 36k. it features a taller profile (360 mm height) and a robust twin-fan setup to move the high volume of air required. Despite the increase in size, it’s designed to remain as quiet and efficient as possible for its class. The AOGH48CRTA-U outdoor unit includes a heavy-duty tropical compressor and a generously sized condenser, enabling it to deliver over 12.5 kW of cooling at T1 and maintain performance in extreme heat (11.14 kW at T3 46 °C). This model is great for situations where one unit must cover what normally might be split between two smaller units, thus reducing the number of outdoor units on rooftops.

 

O General ducted AC indoor unit 1.5 ton

 

Key Features:

  • Massive cooling output – rated 42,700 BTU/h (12.51 kW) at T1, with a maximum capacity up to ~47,900 BTU/h when needed.
  • The inverter technology allows it to scale down to about 3.87 kW at minimum, avoiding excessive power usage when full capacity isn’t required.
  • Efficiency is impressive given the size: EER ~11.6 at T1 (comparable to smaller models) and around 8.8 at T3.
  • The indoor unit’s static pressure capability is maintained at 30–150 Pa, ensuring even large duct networks can be accommodated.
  • Noise levels remain competitive; the indoor unit is around 44 dB(A) on High and 34 dB(A) on Low – which is quite good for a 4 Ton blower.
  • The outdoor unit’s fan and compressor are optimized for quieter operation given the three-phase power (which also balances the electrical load and reduces running current per phase).
  • Installation considerations include the need for three-phase power availability and sufficient space for the larger indoor unit (which measures 360 mm tall and 1.4 m long).
  • This model features all standard control options (often paired with a centralized controller in commercial setups) and includes additional refrigerant charge from the factory for longer line sets (factory charge ~1.85 kg R32 for up to 30 m lines).

 

O General ducted AC indoor unit 1.5 ton

 

Detailed Specifications – ARGH48CMTA-U (Indoor) / AOGH48CRTA-U (Outdoor):

Specification Value (4.0 Ton Model)
Cooling Capacity (T1) 42,700 BTU/h (12.51 kW) — [Min 13,200 – Max 47,900 BTU/h]
Cooling Capacity (T3) 38,000 BTU/h (11.14 kW) — [Min ~17,000 – Max ~46,000 BTU/h]
Energy Efficiency Ratio EER 11.60 BTU/W (≈3.40 W/W) at T1; ~8.8 BTU/W at T3
Power Supply 380–415V 3Ø (3-Phase), 50 Hz (Neutral may be required: 3N~)
Power Input (Cooling) 3.68 kW (T1); 4.32 kW (T3)
Running Current (Total) 5.8 A (T1); 6.9 A (T3) (per phase currents are lower)
Moisture Removal ~4.0 liters/hour
Airflow (Indoor Fan) 2,550 m³/h (1,500 CFM) High; 1,740 m³/h (1,024 CFM) Low
Sound Pressure (Indoor) 44 dB(A) (High) / 34 dB(A) (Low)
Sound Pressure (Outdoor) ~60–63 dB(A) (estimated at full load, at 1m distance)
Dimensions (Indoor Unit) 360 × 1,400 × 850 mm (H×W×D)
Dimensions (Outdoor Unit) 1,158 × 790 × 330 mm (H×W×D) (approx, outdoor form factor larger)
Weight (Indoor/Outdoor) 41.5 kg / 67.0 kg (Net)
Refrigerant R32, 1.85 kg charge (factory)
Piping Connections Liquid: 9.52 mm (3/8"); Gas: 15.88 mm (5/8") – Flare (max pipe length ~50 m)
Static Pressure Range 30–150 Pa (adjustable high static blower)
Operating Range Indoor 18–32 °C; Outdoor 18–55 °C (full tropical spec)
Controller Options Wired remote, group control for multiple units, BMS integration via interface, Wi-Fi (optional adapter)

 

Usage Note: The 4 Ton model is typically used in larger installations; it may require professional HVAC design input to ensure one unit can adequately distribute air to all areas (consider duct zoning if needed). Since it’s a three-phase unit, phase balancing and proper electrical protection (e.g., circuit breaker ~10A per phase, or ~16A 3-phase breaker) are important. During installation, the indoor unit’s size (especially the 360 mm height) means a false ceiling with enough depth is required – check architectural plans for at least 400 mm clearance to fit and service the unit. The refrigerant piping for this model can run longer distances (up to 50 m with additional charge) making it suitable for centralized outdoor equipment arrangements (e.g., all outdoor units on a roof). Ensure the condensate drain is properly installed; the unit includes a strong drain pump that can lift water a good height, but the drain piping must have an outlet lower than the unit eventually. Regular professional servicing is recommended due to the system’s size – e.g., checking phase voltages, tightening electrical connections (as three-phase compressors should be well-monitored for balance), and verifying refrigerant charge annually for peak performance in the UAE’s harsh climate.

 

The 4 Ton model is typically used in larger installations; it may require professional HVAC design input to ensure one unit can adequately distribute air to all areas (consider duct zoning if needed). Since it’s a three-phase unit, phase balancing and proper electrical protection (e.g., circuit breaker ~10A per phase, or ~16A 3-phase breaker) are important. During installation, the indoor unit’s size (especially the 360 mm height) means a false ceiling with enough depth is required – check architectural plans for at least 400 mm clearance to fit and service the unit. The refrigerant piping for this model can run longer distances (up to 50 m with additional charge) making it suitable for centralized outdoor equipment arrangements (e.g., all outdoor units on a roof). Ensure the condensate drain is properly installed; the unit includes a strong drain pump that can lift water a good height, but the drain piping must have an outlet lower than the unit eventually. Regular professional servicing is recommended due to the system’s size – e.g., checking phase voltages, tightening electrical connections (as three-phase compressors should be well-monitored for balance), and verifying refrigerant charge annually for peak performance in the UAE’s harsh climate.